Provided by: waybar_0.12.0-1_amd64 bug

NAME

       waybar - temperature module

DESCRIPTION

       The temperature module displays the current temperature from a thermal zone.

CONFIGURATION

       Addressed by temperature

       thermal-zone:
            typeof: integer
            The thermal zone, as in /sys/class/thermal/.

       hwmon-path:
            typeof: string
            The   temperature   path   to  use,  e.g.  /sys/class/hwmon/hwmon2/temp1_input  instead  of  one  in
       /sys/class/thermal/.
           This can also be an array of strings. In this case, waybar will check each item in the array and  use
           the  first  valid  one.  This  is  suitable  if  you  want to share the same configuration file among
           different machines with different hardware configurations.

       hwmon-path-abs:
            typeof: string
            The path of the hwmon-directory  of  the  device,  e.g.  /sys/devices/pci0000:00/0000:00:18.3/hwmon.
       (Note  that  the  subdirectory hwmon/hwmon#, where # is a number is not part of the path!) Has to be used
       together with input-filename.
           This can also be an array of strings, for which, it just works like hwmon-path.

       input-filename:
            typeof: string
            The temperature filename of your hwmon-path-abs, e.g. temp1_input

       warning-threshold:
            typeof: integer
            The threshold before it is considered warning (Celsius).

       critical-threshold:
            typeof: integer
            The threshold before it is considered critical (Celsius).

       interval:
            typeof: integer
            default: 10
            The interval in which the information gets polled.

       format-warning:
            typeof: string
            The format to use when temperature is considered warning

       format-critical:
            typeof: string
            The format to use when temperature is considered critical

       format:
            typeof: string
            default: {temperatureC}°C
            The format (Celsius/Fahrenheit/Kelvin) in which the temperature should be displayed.

       format-icons:
            typeof: array
            Based on the current temperature (Celsius) and critical-threshold if  available,  the  corresponding
       icon gets selected. The order is low to high.

       tooltip-format:
            typeof: string
            default: {temperatureC}°C
            The format for the tooltip

       rotate:
            typeof: integer
            Positive value to rotate the text label (in 90 degree increments).

       max-length:
            typeof: integer
            The maximum length in characters the module should display.

       min-length:
            typeof: integer
            The minimum length in characters the module should accept.

       align:
            typeof: float
            The alignment of the label within the module, where 0 is left-aligned and 1 is right-aligned. If the
       module is rotated, it will follow the flow of the text.

       justify:
            typeof: string
            The  alignment  of the text within the module's label, allowing options 'left', 'right', or 'center'
       to define the positioning.

       on-click:
            typeof: string
            Command to execute when you click on the module.

       on-click-middle:
            typeof: string
            Command to execute when middle-clicked on the module using mousewheel.

       on-click-right:
            typeof: string
            Command to execute when you right-click on the module.

       on-update:
            typeof: string
            Command to execute when the module is updated.

       on-scroll-up:
            typeof: string
            Command to execute when scrolling up on the module.

       on-scroll-down:
            typeof: string
            Command to execute when scrolling down on the module.

       smooth-scrolling-threshold:
            typeof: double
            Threshold to be used when scrolling.

       tooltip:
            typeof: bool
            default: true
            Option to disable tooltip on hover.

       menu:
            typeof: string
            Action that popups the menu.

       menu-file:
            typeof: string
            Location of the menu descriptor file. There need to be an element of type
           GtkMenu with id menu

       menu-actions:
            typeof: array
            The actions corresponding to the buttons of the menu.

       expand:
            typeof: bool
            default: false
            Enables this module to consume all left over space dynamically.

FORMAT REPLACEMENTS

       {temperatureC}: Temperature in Celsius.

       {temperatureF}: Temperature in Fahrenheit.

       {temperatureK}: Temperature in Kelvin.

EXAMPLES

            "temperature": {
                // "thermal-zone": 2,
                // "hwmon-path": ["/sys/class/hwmon/hwmon2/temp1_input", "/sys/class/thermal/thermal_zone0/temp"],
                // "critical-threshold": 80,
                // "format-critical": "{temperatureC}°C ",
                "format": "{temperatureC}°C "
           }

STYLE

#temperature#temperature.critical

                                                   2025-02-21                              waybar-temperature(5)