Provided by: ovn-common_24.09.0-1ubuntu0.1_amd64 bug

NAME

       ovn-controller - Open Virtual Network local controller

SYNOPSIS

       ovn-controller [options] [ovs-database]

DESCRIPTION

       ovn-controller  is  the  local controller daemon for OVN, the Open Virtual Network. It connects up to the
       OVN Southbound database (see ovn-sb(5)) over the OVSDB protocol, and down to the  Open  vSwitch  database
       (see  ovs-vswitchd.conf.db(5))  over  the  OVSDB  protocol  and  to  ovs-vswitchd(8)  via  OpenFlow. Each
       hypervisor and software gateway in an OVN deployment runs its own  independent  copy  of  ovn-controller;
       thus, ovn-controller’s downward connections are machine-local and do not run over a physical network.

ACL LOGGING

       ACL  log  messages are logged through ovn-controller’s logging mechanism. ACL log entries have the module
       acl_log at log level info. Configuring logging is described below in the Logging Options section.

OPTIONS

   Daemon Options
       --pidfile[=pidfile]
              Causes a file (by default, program.pid) to be created indicating the PID of the  running  process.
              If the pidfile argument is not specified, or if it does not begin with /, then it is created in .

              If --pidfile is not specified, no pidfile is created.

       --overwrite-pidfile
              By  default, when --pidfile is specified and the specified pidfile already exists and is locked by
              a running process, the daemon refuses to start. Specify --overwrite-pidfile to cause it to instead
              overwrite the pidfile.

              When --pidfile is not specified, this option has no effect.

       --detach
              Runs this program as a background process. The process forks, and in the child  it  starts  a  new
              session,  closes  the standard file descriptors (which has the side effect of disabling logging to
              the console), and changes its current directory to the  root  (unless  --no-chdir  is  specified).
              After the child completes its initialization, the parent exits.

       --monitor
              Creates an additional process to monitor this program. If it dies due to a signal that indicates a
              programming  error  (SIGABRT,  SIGALRM,  SIGBUS,  SIGFPE,  SIGILL,  SIGPIPE,  SIGSEGV, SIGXCPU, or
              SIGXFSZ) then the monitor process starts a new copy of it. If the daemon dies or exits for another
              reason, the monitor process exits.

              This option is normally used with --detach, but it also functions without it.

       --no-chdir
              By default, when --detach is specified, the daemon changes its current working  directory  to  the
              root  directory  after  it  detaches.  Otherwise,  invoking  the  daemon  from a carelessly chosen
              directory would prevent the  administrator  from  unmounting  the  file  system  that  holds  that
              directory.

              Specifying  --no-chdir  suppresses  this behavior, preventing the daemon from changing its current
              working directory. This may be useful for collecting core files, since it is  common  behavior  to
              write core dumps into the current working directory and the root directory is not a good directory
              to use.

              This option has no effect when --detach is not specified.

       --no-self-confinement
              By  default  this  daemon  will  try  to  self-confine  itself to work with files under well-known
              directories determined at build time. It is better to stick with this default behavior and not  to
              use this flag unless some other Access Control is used to confine daemon. Note that in contrast to
              other  access  control  implementations that are typically enforced from kernel-space (e.g. DAC or
              MAC), self-confinement is imposed from the user-space  daemon  itself  and  hence  should  not  be
              considered  as a full confinement strategy, but instead should be viewed as an additional layer of
              security.

       --user=user:group
              Causes this program to run as a different user specified in user:group, thus dropping most of  the
              root privileges. Short forms user and :group are also allowed, with current user or group assumed,
              respectively. Only daemons started by the root user accepts this argument.

              On  Linux,  daemons  will  be  granted CAP_IPC_LOCK and CAP_NET_BIND_SERVICES before dropping root
              privileges. Daemons that interact with a datapath, such as ovs-vswitchd,  will  be  granted  three
              additional  capabilities,  namely CAP_NET_ADMIN, CAP_NET_BROADCAST and CAP_NET_RAW. The capability
              change will apply even if the new user is root.

              On Windows, this option is not currently supported. For security reasons, specifying  this  option
              will cause the daemon process not to start.

   Logging Options
       -v[spec]
       --verbose=[spec]
            Sets  logging  levels. Without any spec, sets the log level for every module and destination to dbg.
            Otherwise, spec is a list of words separated by spaces or commas or colons,  up  to  one  from  each
            category below:

            •      A  valid  module name, as displayed by the vlog/list command on ovs-appctl(8), limits the log
                   level change to the specified module.

            •      syslog, console, or file, to limit the log level change to only to the  system  log,  to  the
                   console,  or  to  a  file,  respectively.  (If  --detach  is specified, the daemon closes its
                   standard file descriptors, so logging to the console will have no effect.)

                   On Windows platform, syslog is accepted  as  a  word  and  is  only  useful  along  with  the
                   --syslog-target option (the word has no effect otherwise).

            •      off,  emer, err, warn, info, or dbg, to control the log level. Messages of the given severity
                   or higher will be logged, and messages of lower severity will be filtered  out.  off  filters
                   out all messages. See ovs-appctl(8) for a definition of each log level.

            Case is not significant within spec.

            Regardless  of  the log levels set for file, logging to a file will not take place unless --log-file
            is also specified (see below).

            For compatibility with older versions of OVS, any is accepted as a word but has no effect.

       -v
       --verbose
            Sets the maximum logging verbosity level, equivalent to --verbose=dbg.

       -vPATTERN:destination:pattern
       --verbose=PATTERN:destination:pattern
            Sets the log pattern for destination to pattern. Refer to ovs-appctl(8) for  a  description  of  the
            valid syntax for pattern.

       -vFACILITY:facility
       --verbose=FACILITY:facility
            Sets the RFC5424 facility of the log message. facility can be one of kern, user, mail, daemon, auth,
            syslog,  lpr,  news,  uucp,  clock,  ftp, ntp, audit, alert, clock2, local0, local1, local2, local3,
            local4, local5, local6 or local7. If this option is not specified, daemon is used as the default for
            the local system syslog and local0 is used while sending a message to the target  provided  via  the
            --syslog-target option.

       --log-file[=file]
            Enables logging to a file. If file is specified, then it is used as the exact name for the log file.
            The default log file name used if file is omitted is /var/log/ovn/program.log.

       --syslog-target=host:port
            Send  syslog  messages  to  UDP  port  on host, in addition to the system syslog. The host must be a
            numerical IP address, not a hostname.

       --syslog-method=method
            Specify method as how syslog messages should be sent to  syslog  daemon.  The  following  forms  are
            supported:

            •      libc,  to  use  the  libc syslog() function. Downside of using this options is that libc adds
                   fixed prefix to every message before it is actually sent to the syslog daemon  over  /dev/log
                   UNIX domain socket.

            •      unix:file,  to use a UNIX domain socket directly. It is possible to specify arbitrary message
                   format with this option. However, rsyslogd 8.9 and  older  versions  use  hard  coded  parser
                   function  anyway  that  limits  UNIX  domain socket use. If you want to use arbitrary message
                   format with older rsyslogd versions, then use UDP socket to localhost IP address instead.

            •      udp:ip:port, to use a UDP socket. With this method it is possible to  use  arbitrary  message
                   format  also  with  older  rsyslogd.  When  sending  syslog  messages  over  UDP socket extra
                   precaution needs to be taken into account, for example, syslog daemon needs to be  configured
                   to  listen  on  the  specified  UDP port, accidental iptables rules could be interfering with
                   local syslog traffic and there are some security considerations that apply  to  UDP  sockets,
                   but do not apply to UNIX domain sockets.

            •      null, to discard all messages logged to syslog.

            The default is taken from the OVS_SYSLOG_METHOD environment variable; if it is unset, the default is
            libc.

   PKI Options
       PKI  configuration  is  required in order to use SSL for the connections to the Northbound and Southbound
       databases.

              -p privkey.pem
              --private-key=privkey.pem
                   Specifies a  PEM  file  containing  the  private  key  used  as  identity  for  outgoing  SSL
                   connections.

              -c cert.pem
              --certificate=cert.pem
                   Specifies  a PEM file containing a certificate that certifies the private key specified on -p
                   or --private-key to be trustworthy.  The  certificate  must  be  signed  by  the  certificate
                   authority (CA) that the peer in SSL connections will use to verify it.

              -C cacert.pem
              --ca-cert=cacert.pem
                   Specifies  a  PEM  file containing the CA certificate for verifying certificates presented to
                   this program by SSL peers. (This may be the same certificate that SSL peers use to verify the
                   certificate specified on -c or --certificate, or it may be a different one, depending on  the
                   PKI design in use.)

              -C none
              --ca-cert=none
                   Disables  verification  of  certificates  presented  by SSL peers. This introduces a security
                   risk, because it means that certificates cannot be verified to  be  those  of  known  trusted
                   hosts.

              --bootstrap-ca-cert=cacert.pem
                     When  cacert.pem exists, this option has the same effect as -C or --ca-cert. If it does not
                     exist, then the executable will attempt to obtain the CA certificate from the SSL  peer  on
                     its  first  SSL  connection and save it to the named PEM file. If it is successful, it will
                     immediately drop the connection and reconnect, and from then on all SSL connections must be
                     authenticated by a certificate signed by the CA certificate thus obtained.

                     This option exposes the SSL connection to a man-in-the-middle attack obtaining the  initial
                     CA certificate, but it may be useful for bootstrapping.

                     This  option  is  only  useful  if the SSL peer sends its CA certificate as part of the SSL
                     certificate chain. The SSL protocol does not require the server to send the CA certificate.

                     This option is mutually exclusive with -C and --ca-cert.

              --peer-ca-cert=peer-cacert.pem
                     Specifies a PEM file that contains one or more  additional  certificates  to  send  to  SSL
                     peers.  peer-cacert.pem  should  be  the  CA  certificate  used  to  sign the program’s own
                     certificate, that is, the certificate specified on -c or --certificate.  If  the  program’s
                     certificate  is  self-signed, then --certificate and --peer-ca-cert should specify the same
                     file.

                     This option is not useful in normal operation, because the SSL peer must already  have  the
                     CA certificate for the peer to have any confidence in the program’s identity. However, this
                     offers  a  way  for  a  new  installation  to bootstrap the CA certificate on its first SSL
                     connection.

   Other Options
       -h
       --help
            Prints a brief help message to the console.

       -V
       --version
            Prints version information to the console.

CONFIGURATION

       ovn-controller retrieves most of its configuration information from the local Open vSwitch’s ovsdb-server
       instance. The default location is db.sock in  the  local  Open  vSwitch’s  "run"  directory.  It  may  be
       overridden  by  specifying  the ovs-database argument as an OVSDB active or passive connection method, as
       described in ovsdb(7).

       ovn-controller assumes it gets configuration information from the  following  keys  in  the  Open_vSwitch
       table of the local OVS instance:

              external_ids:system-id
                     The  chassis  name to use in the Chassis table. Changing the system-id while ovn-controller
                     is running is not directly supported. Users have two options: either first gracefully  stop
                     ovn-controller  or  manually  delete  the  stale  Chassis and Chassis_Private records after
                     changing the  system-id.  Note  that  the  chassis  name  can  also  be  provided  via  the
                     system-id-override file in the local OVN "etc" directory or via the -n command-line option.
                     The  following  precedence is used: first, the command-line option is read; if not present,
                     the system-id-override file is read; if not  present,  then  the  name  configured  in  the
                     database is used.

              external_ids:hostname
                     The hostname to use in the Chassis table.

              external_ids:ovn-bridge
                     The  integration bridge to which logical ports are attached. The default is br-int. If this
                     bridge does not exist when ovn-controller starts, it will be created automatically with the
                     default configuration suggested in ovn-architecture(7). When more than one controllers  are
                     running  on  the  same host, external_ids:ovn-bridge-CHASSIS_NAME should be set for each of
                     them, pointing to a unique bridge. This is required to avoid controllers stepping  on  each
                     others’ feet.

              external_ids:ovn-bridge-datapath-type
                     This  configuration  is  optional. If set, then the datapath type of the integration bridge
                     will be set to the configured value. If this option is not set,  then  ovn-controller  will
                     not modify the existing datapath-type of the integration bridge.

              external_ids:ovn-remote
                     The  OVN  database  that this system should connect to for its configuration, in one of the
                     same forms documented above for the ovs-database.

              external_ids:ovn-monitor-all
                     A boolean value that tells if ovn-controller should monitor all records of tables  in  ovs-
                     database.  If set to false, it will conditionally monitor the records that is needed in the
                     current chassis.

                     It is more efficient to set it to true in use cases where the chassis would anyway need  to
                     monitor  most  of  the records in OVN Southbound database, which would save the overhead of
                     conditions  processing,  especially  for  server  side.  Typically,  set  it  to  true  for
                     environments that all workloads need to be reachable from each other.

                     NOTE:  for  efficiency  and  scalability in common scenarios ovn-controller unconditionally
                     monitors all sub-ports (ports with  parent_port  set)  regardless  of  the  ovn-monitor-all
                     value.

                     Default value is false.

              external_ids:ovn-remote-probe-interval
                     The  inactivity  probe  interval of the connection to the OVN database, in milliseconds. If
                     the value is zero, it disables the connection keepalive feature.

                     If the value is nonzero, then it will be forced to a value of at least 1000 ms.

              external_ids:ovn-encap-type
                     The encapsulation type that a  chassis  should  use  to  connect  to  this  node.  Multiple
                     encapsulation types may be specified with a comma-separated list. Each listed encapsulation
                     type will be paired with ovn-encap-ip.

                     Supported tunnel types for connecting hypervisors and gateways are geneve, vxlan, and stt.

                     Due  to  the  limited  amount  of  metadata  in  vxlan, the capabilities and performance of
                     connected gateways and hypervisors will be reduced versus other tunnel formats.

              external_ids:ovn-encap-ip
                     The IP address that a chassis should use to connect to this node using encapsulation  types
                     specified  by external_ids:ovn-encap-type. Multiple encapsulation IPs may be specified with
                     a comma-separated list.

                     In scenarios where multiple encapsulation IPs are present, distinct tunnels are established
                     for  each  remote  chassis.  These   tunnels   are   differentiated   by   setting   unique
                     options:local_ip  and options:remote_ip values in the tunnel interface. When transmitting a
                     packet  to  a  remote   chassis,   the   selection   of   local_ip   is   guided   by   the
                     Interface:external_ids:encap-ip  from the local OVSDB, corresponding to the VIF originating
                     the packet, if specified. The Interface:external_ids:encap-ip setting of the  VIF  is  also
                     populated  to  the  Port_Binding  table  in  the  OVN  SB  database  via  the encap column.
                     Consequently, when a remote chassis needs to send a packet  to  a  port-binding  associated
                     with  this  VIF, it utilizes the tunnel with the appropriate options:remote_ip that matches
                     the ip in Port_Binding:encap. This mechanism is particularly beneficial  for  chassis  with
                     multiple  physical  interfaces  designated for tunneling, where each interface is optimized
                     for handling specific traffic associated with particular VIFs.

              external_ids:ovn-encap-ip-default
                     When ovn-encap-ip contains multiple IPs, this field indicates the default one.

              external_ids:ovn-encap-df_default
                     indicates the DF flag handling of the encapulation. Set to true to set the DF flag for  new
                     data paths or false to clear the DF flag.

              external_ids:ovn-bridge-mappings
                     A  list  of  key-value  pairs  that  map a physical network name to a local ovs bridge that
                     provides connectivity to that network. An example value mapping two physical network  names
                     to two ovs bridges would be: physnet1:br-eth0,physnet2:br-eth1.

              external_ids:ovn-encap-csum
                     ovn-encap-csum  indicates that encapsulation checksums can be transmitted and received with
                     reasonable performance. It is a hint to senders transmitting data to this chassis that they
                     should use checksums to protect OVN metadata. Set to true to enable or  false  to  disable.
                     Depending  on  the  capabilities  of  the  network  interface  card, enabling encapsulation
                     checksum may incur  performance  loss.  In  such  cases,  encapsulation  checksums  can  be
                     disabled.

              external_ids:ovn-encap-tos
                     ovn-encap-tos  indicates  the  value  to be applied to OVN tunnel interface’s option:tos as
                     specified in the Open_vSwitch database Interface table. Please refer to Open VSwitch Manual
                     for details.

              external_ids:ovn-cms-options
                     A list of options that will be consumed by the  CMS  Plugin  and  which  specific  to  this
                     particular chassis. An example would be: cms_option1,cms_option2:foo.

              external_ids:ovn-transport-zones
                     The  transport  zone(s)  that  this  chassis  belongs to. Transport zones is a way to group
                     different chassis so that tunnels are only formed between members  of  the  same  group(s).
                     Multiple  transport  zones  may  be  specified  with  a  comma-separated list. For example:
                     tz1,tz2,tz3.

                     If not set, the Chassis will be considered part of a default transport zone.

              external_ids:ovn-chassis-mac-mappings
                     A list of key-value pairs that map a chassis specific mac to a physical  network  name.  An
                     example   value  mapping  two  chassis  macs  to  two  physical  network  names  would  be:
                     physnet1:aa:bb:cc:dd:ee:ff,physnet2:a1:b2:c3:d4:e5:f6.  These  are  the  macs   that   ovn-
                     controller  will  replace  a  router  port  mac with, if packet is going from a distributed
                     router port on vlan type logical switch.

              external_ids:ovn-is-interconn
                     The boolean flag indicates if the chassis is used as an interconnection gateway.

              external_ids:ovn-match-northd-version
                     The boolean flag indicates if ovn-controller needs to check  ovn-northd  version.  If  this
                     flag  is  set  to  true  and the ovn-northd’s version (reported in the Southbound database)
                     doesn’t match with the ovn-controller’s internal version, then it will stop processing  the
                     southbound  and  local Open vSwitch database changes. The default value is considered false
                     if this option is not defined.

              external_ids:ovn-ofctrl-wait-before-clear
                     The  time,  in  milliseconds,  to  wait  before  clearing  flows  in  OVS  after   OpenFlow
                     connection/reconnection  during  ovn-controller initialization. The purpose of this wait is
                     to give time for ovn-controller to compute the new flows before clearing existing ones,  to
                     avoid   data   plane  down  time  during  ovn-controller  restart/upgrade  at  large  scale
                     environments where recomputing the flows takes more than a few seconds or even  longer.  It
                     is  difficult  for  ovn-controller  to determine when the new flows computing is completed,
                     because of the dynamics in the cloud environments,  which  is  why  this  configuration  is
                     provided  for  users  to adjust based on the scale of the environment. By default, it is 0,
                     which means clearing existing flows without waiting. Not setting the value, or  setting  it
                     too  small, may result in data plane down time during upgrade/restart, while setting it too
                     big may result in unnecessary extra control plane latency of applying new  changes  of  CMS
                     during  upgrade/restart. In most cases, a slightly bigger value is not harmful, because the
                     extra control plane latency happens only once during the  OpenFlow  connection.  To  get  a
                     reasonable  range  of  the  value setting, it is recommended to run the below commands on a
                     node in the target environment and then set  this  configuration  to  twice  the  value  of
                     Maximum shown in the output of the second command.

                     •      ovn-appctl -t ovn-controller inc-engine/recomputeovn-appctl -t ovn-controller stopwatch/show flow-generation

              external_ids:ovn-enable-lflow-cache
                     The  boolean  flag  indicates  if ovn-controller should enable/disable the logical flow in-
                     memory cache it uses when processing Southbound database logical flow changes.  By  default
                     caching is enabled.

              external_ids:ovn-limit-lflow-cache
                     When  used,  this  configuration  value determines the maximum number of logical flow cache
                     entries ovn-controller may create when the logical flow cache is enabled.  By  default  the
                     size of the cache is unlimited.

              external_ids:ovn-memlimit-lflow-cache-kb
                     When  used,  this configuration value determines the maximum size of the logical flow cache
                     (in KB) ovn-controller may create when the logical flow cache is enabled.  By  default  the
                     size of the cache is unlimited.

              external_ids:ovn-trim-limit-lflow-cache
                     When  used, this configuration value sets the minimum number of entries in the logical flow
                     cache starting with which automatic memory trimming is performed. By default this is set to
                     10000 entries.

              external_ids:ovn-trim-wmark-perc-lflow-cache
                     When used, this configuration value sets the percentage from the high watermark  number  of
                     entries in the logical flow cache under which automatic memory trimming is performed. E.g.,
                     if the trim watermark percentage is set to 50%, automatic memory trimming happens only when
                     the  number of entries in the logical flow cache gets reduced to less than half of the last
                     measured high watermark. By default this is set to 50.

              external_ids:ovn-trim-timeout-ms
                     When used, this configuration value specifies the time, in  milliseconds,  since  the  last
                     logical flow cache operation after which ovn-controller performs memory trimming regardless
                     of how many entries there are in the cache. By default this is set to 30000 (30 seconds).

              external_ids:garp-max-timeout-sec
                     When  used, this configuration value specifies the maximum timeout (in seconds) between two
                     consecutive GARP packets sent by ovn-controller. ovn-controller by  default  sends  just  4
                     GARP packets with an exponential backoff timeout. Setting external_ids:garp-max-timeout-sec
                     allows to cap for the exponential backoff used by ovn-controller to send GARPs packets.

              external_ids:ovn-bridge-remote
                     Connection  to  the  OVN management bridge in OvS. It defaults to unix:br-int.mgmt when not
                     specified.

              external_ids:ovn-bridge-remote-probe-interval
                     The inactivity  probe  interval  of  the  connection  to  the  OVN  management  bridge,  in
                     milliseconds. It defaults to zero. If the value is zero, it disables the inactivity probe.

       Most  of  configuration  options  listed  above  can  also  be  set  for  a  particular chassis name (see
       external_ids:system-id     for    more    information).    This    can    be    achieved    by    setting
       external_ids:option-[chassis]      instead      of      external_ids:option.     For     example,     set
       external_ids:ovn-encap-ip-otherhv to use a particular  IP  address  for  the  controller  instance  named
       otherhv. Name specific configuration options always override any global options set in the database.

       Chassis-specific  configuration options in the database plus the ability to configure the chassis name to
       use via the system-id-override file or command line allows to run multiple ovn-controller instances  with
       unique chassis names on the same host using the same vswitchd instance. This may be useful when running a
       hybrid setup with more than one CMS managing ports on the host, or to use different datapath types on the
       same  host.  Also  note  that this ability is highly experimental and has known limitations (for example,
       stateful ACLs are not supported). Use at your own risk.

       ovn-controller reads the following values from the Open_vSwitch database of the local OVS instance:

              datapath-type from Bridge table
                     This value is read from local OVS integration bridge row of Bridge table and  populated  in
                     other_config:datapath-type of the Chassis table in the OVN_Southbound database.

              iface-types from Open_vSwitch table
                     This   value  is  populated  in  external_ids:iface-types  of  the  Chassis  table  in  the
                     OVN_Southbound database.

              private_key, certificate, ca_cert, and bootstrap_ca_cert from SSL table
                     These values provide the SSL configuration  used  for  connecting  to  the  OVN  southbound
                     database server when an SSL connection type is configured via external_ids:ovn-remote. Note
                     that   this   SSL  configuration  can  also  be  provided  via  command-line  options,  the
                     configuration in the database takes precedence if both are present.

OPEN VSWITCH DATABASE USAGE

       ovn-controller uses a number of external_ids keys in the Open vSwitch database to keep track of ports and
       interfaces. For proper operation, users should not change or clear these keys:

              external_ids:ovn-chassis-id in the Port table
                     The presence of this key identifies a tunnel port within  the  integration  bridge  as  one
                     created  by  ovn-controller  to  reach a remote chassis. Its value is the chassis ID of the
                     remote chassis.

              external_ids:ct-zone-range in the Open_vSwitch table
                     The presence of  this  key  identifies  a  minimum  and  maximum  values  for  ct-zone  ids
                     dynamically  selected  by  ovn-controller  (boundaries  are included in the range). Minimum
                     value is 1 while maximum value is 65535.

              external_ids:ct-zone-* in the Bridge table
                     Logical ports and gateway routers are assigned a connection tracking zone by ovn-controller
                     for stateful services. To keep state across restarts  of  ovn-controller,  these  keys  are
                     stored  in  the  integration  bridge’s Bridge table. The name contains a prefix of ct-zone-
                     followed by the name of the logical port or gateway router’s zone key. The value  for  this
                     key identifies the zone used for this port.

              external_ids:ovn-localnet-port in the Port table
                     The  presence  of  this  key  identifies  a  patch port as one created by ovn-controller to
                     connect the integration bridge and another bridge to implement a localnet logical port. Its
                     value is the name of the logical port with type set to localnet that the  port  implements.
                     See external_ids:ovn-bridge-mappings, above, for more information.

                     Each  localnet logical port is implemented as a pair of patch ports, one in the integration
                     bridge, one in a different bridge, with the same external_ids:ovn-localnet-port value.

              external_ids:ovn-l2gateway-port in the Port table
                     The presence of this key identifies a patch  port  as  one  created  by  ovn-controller  to
                     connect  the  integration  bridge and another bridge to implement a l2gateway logical port.
                     Its value is the name of the logical  port  with  type  set  to  l2gateway  that  the  port
                     implements. See external_ids:ovn-bridge-mappings, above, for more information.

                     Each l2gateway logical port is implemented as a pair of patch ports, one in the integration
                     bridge, one in a different bridge, with the same external_ids:ovn-l2gateway-port value.

              external-ids:ovn-l3gateway-port in the Port table
                     This  key identifies a patch port as one created by ovn-controller to implement a l3gateway
                     logical port. Its value is the name of the logical port with type set  to  l3gateway.  This
                     patch port is similar to the OVN logical patch port, except that l3gateway port can only be
                     bound to a particular chassis.

              external-ids:ovn-logical-patch-port in the Port table
                     This  key  identifies  a  patch  port  as one created by ovn-controller to implement an OVN
                     logical patch port within the integration bridge. Its value is the name of the OVN  logical
                     patch port that it implements.

              external-ids:ovn-startup-ts in the Bridge table
                     This  key  represents  the  timestamp (in milliseconds) at which ovn-controller process was
                     started.

              external-ids:ovn-nb-cfg in the Bridge table
                     This key represents the last known  OVN_Southbound.SB_Global.nb_cfg  value  for  which  all
                     flows have been successfully installed in OVS.

              external-ids:ovn-nb-cfg-ts in the Bridge table
                     This    key    represents   the   timestamp   (in   milliseconds)   of   the   last   known
                     OVN_Southbound.SB_Global.nb_cfg value for which all flows have been successfully  installed
                     in OVS.

              external_ids:ovn-installed and external_ids:ovn-installed-ts in the Interface table
                     This  key is set after all openflow operations corresponding to the OVS interface have been
                     processed by ovs-vswitchd. At the same time a timestamp, in milliseconds since  the  epoch,
                     is stored in external_ids:ovn-installed-ts.

OVN SOUTHBOUND DATABASE USAGE

       ovn-controller reads from much of the OVN_Southbound database to guide its operation. ovn-controller also
       writes to the following tables:

              Chassis
                     Upon startup, ovn-controller creates a row in this table to represent its own chassis. Upon
                     graceful  termination,  e.g.  with  ovs-appctl  -t  ovn-controller  exit (but not SIGTERM),
                     ovn-controller removes its row.

              Encap  Upon startup, ovn-controller creates a row or rows in this table that represent the  tunnel
                     encapsulations  by  which  its  chassis can be reached, and points its Chassis row to them.
                     Upon graceful termination, ovn-controller removes these rows.

              Port_Binding
                     At runtime, ovn-controller sets the chassis columns of  ports  that  are  resident  on  its
                     chassis  to  point  to its Chassis row, and, conversely, clears the chassis column of ports
                     that point to its Chassis row but are no longer resident on its chassis. The chassis column
                     has a weak reference type, so when ovn-controller gracefully exits and removes its  Chassis
                     row, the database server automatically clears any remaining references to that row.

              MAC_Binding
                     At  runtime,  ovn-controller  updates  the  MAC_Binding  table as instructed by put_arp and
                     put_nd logical actions. These changes persist beyond the lifetime of ovn-controller.

RUNTIME MANAGEMENT COMMANDS

       ovs-appctl can send commands to a running ovn-controller process. The currently  supported  commands  are
       described below.

              exit   Causes ovn-controller to gracefully terminate.

              ct-zone-list
                     Lists each local logical port and its connection tracking zone.

              meter-table-list
                     Lists each meter table entry and its local meter id.

              group-table-list
                     Lists each group table entry and its local group id.

              inject-pkt microflow
                     Injects  microflow  into  the  connected  Open  vSwitch instance. microflow must contain an
                     ingress logical port (inport argument) that is present on the Open vSwitch instance.

                     The microflow argument describes the packet whose forwarding is to  be  simulated,  in  the
                     syntax of an OVN logical expression, as described in ovn-sb(5), to express constraints. The
                     parser  understands  prerequisites; for example, if the expression refers to ip4.src, there
                     is no need to explicitly state ip4 or eth.type == 0x800.

              connection-status
                     Show OVN SBDB connection status for the chassis.

              recompute
                     Trigger a full compute iteration in ovn-controller based on the contents of the  Southbound
                     database and local OVS database.

                     This  command  is  intended to use only in the event of a bug in the incremental processing
                     engine in ovn-controller to avoid inconsistent states. It should  therefore  be  used  with
                     care as full recomputes are cpu intensive.

              sb-cluster-state-reset
                     Reset southbound database cluster status when databases are destroyed and rebuilt.

                     If  all databases in a clustered southbound database are removed from disk, then the stored
                     index of all databases will be reset to zero. This will cause ovn-controller to  be  unable
                     to  read  or  write  to  the southbound database, because it will always detect the data as
                     stale. In such a case, run this command so that ovn-controller will reset its  local  index
                     so that it can interact with the southbound database again.

              debug/delay-nb-cfg-report seconds
                     This  command  is  used  to delay ovn-controller updating the nb_cfg back to OVN_Southbound
                     database. This is useful when ovn-nbctl --wait=hv is used to measure end-to-end latency  in
                     a large scale environment. See ovn-nbctl(8) for more details.

              lflow-cache/flush
                     Flushes the ovn-controller logical flow cache.

              lflow-cache/show-stats
                     Displays logical flow cache statistics: enabled/disabled, per cache type entry counts.

              inc-engine/show-stats
                     Display  ovn-controller  engine  counters. For each engine node the following counters have
                     been added:

                     •      recomputecomputecancel

              inc-engine/show-stats engine_node_name counter_name
                     Display  the  ovn-controller  engine  counter(s)  for   the   specified   engine_node_name.
                     counter_name is optional and can be one of recompute, compute or cancel.

              inc-engine/clear-stats
                     Reset ovn-controller engine counters.

OVN 24.09.0                                      ovn-controller                                ovn-controller(8)