Provided by: smokeping_2.8.2+ds-1_all bug

NAME

       Smokeping::probes::FPingContinuous - FPingContinuous Probe for SmokePing

SYNOPSIS

        *** Probes ***

        +FPingContinuous

        binary = /usr/bin/fping # mandatory
        hostinterval = 1.5
        offset = 50%
        packetsize = 5000
        pings = 20
        sourceaddress = 192.168.0.1
        step = 300
        timeout = 1.5
        tos = 0x20
        usestdout = false

        # The following variables can be overridden in each target section
        /^influx_.+/ = influx_location = In the basement

        # [...]

        *** Targets ***

        probe = FPingContinuous # if this should be the default probe

        # [...]

        + mytarget
        # probe = FPingContinuous # if the default probe is something else
        host = my.host
        /^influx_.+/ = influx_location = In the basement

DESCRIPTION

       Integrates FPingContinuous as a probe into smokeping. The variable binary must point to your copy of the
       FPing program.  If it is not installed on your system yet, you can get a slightly enhanced version from
       "pub" in www.smokeping.org.

       The (optional) packetsize option lets you configure the packetsize for the pings sent.

       Continuous output is normally sent to stdout, but you can set usestdout to 'false' to make smokeping read
       stderr instead of stdout.

       The FPing manpage has the following to say on this topic:

       Number of bytes of ping data to send.  The minimum size (normally 12) allows room for the data that fping
       needs to do its work (sequence number, timestamp).  The reported received data size includes the IP
       header (normally 20 bytes) and ICMP header (8 bytes), so the minimum total size is 40 bytes.  Default is
       56, as in ping. Maximum is the theoretical maximum IP datagram size (64K), though most systems limit this
       to a smaller, system-dependent number.

VARIABLES

       Supported probe-specific variables:

       binary
           The location of your fping binary.

           Example value: /usr/bin/fping

           This setting is mandatory.

       hostinterval
           The  fping  "-p"  parameter,  but  in  (possibly  fractional)  seconds  rather than milliseconds, for
           consistency with other Smokeping probes. From fping(1):

           This parameter sets the time that fping  waits between successive packets to an individual target.

           Example value: 1.5

       offset
           If you run many probes concurrently you may want to prevent them from hitting your network all at the
           same time. Using the probe-specific offset parameter you can change the point in time when each probe
           will be run. Offset is specified in % of total interval, or alternatively as 'random', and the offset
           from the 'General' section is used if nothing is specified here. Note that this  does  NOT  influence
           the  rrds  itself, it is just a matter of when data acquisition is initiated.  (This variable is only
           applicable if the variable 'concurrentprobes' is set in the 'General' section.)

           Example value: 50%

       packetsize
           The ping packet size (in the range of 12-64000 bytes).

           Example value: 5000

       pings
           How many pings should be sent to each target, if different from the global  value  specified  in  the
           Database  section.  Note  that the number of pings in the RRD files is fixed when they are originally
           generated, and if you change this parameter afterwards, you'll have to delete the old  RRD  files  or
           somehow convert them.

           Example value: 20

       sourceaddress
           The fping "-S" parameter . From fping(1):

           Set source address.

           Example value: 192.168.0.1

       step
           Duration  of the base interval that this probe should use, if different from the one specified in the
           'Database' section. Note that the step in the RRD files is fixed when they are originally  generated,
           and  if  you change the step parameter afterwards, you'll have to delete the old RRD files or somehow
           convert them. (This variable is only applicable if the variable  'concurrentprobes'  is  set  in  the
           'General' section.)

           Example value: 300

       timeout
           The  fping  "-t"  parameter,  but  in  (possibly  fractional)  seconds  rather than milliseconds, for
           consistency with other Smokeping probes. Note that as Smokeping uses the fping 'counting' mode  (-C),
           this apparently only affects the last ping.

           Example value: 1.5

       tos Set  the type of service (TOS) of outgoing ICMP packets.  You need at laeast fping-2.4b2_to3-ipv6 for
           this to work. Find a copy on www.smokeping.org/pub.

           Example value: 0x20

       usestdout
           Listen for FPing output on stdout instead of stderr  ...  (continuous  output  is  normally  sent  to
           stdout).

           Example value: false

AUTHORS

       Steven Wilton <swilton@fluentit.com.au> Tobias Oetiker <tobi@oetiker.ch>

2.8.2                                              2024-02-04                Smokeping_probes_FPingContinuous(3)