Provided by: pcp_6.2.0-1.1build4_amd64 bug

NAME

       pmlogger - create an archive for performance metrics

SYNOPSIS

       pmlogger  [-CLNoPruy?]   [-c  conffile] [-d directory] [-h host] [-H hostname] [-I version] [-K spec] [-l
       logfile] [-m note] [-n pmnsfile] [-p pid] [-s endsize] [-t  interval]  [-T  endtime]  [-U  username]  [-v
       volsize] [-V version] [-x fd] archive

DESCRIPTION

       pmlogger  creates  the  archives  of  performance  metric  values  that  may  be ``played back'' by other
       Performance Co-Pilot (see PCPIntro(1)) tools.  These  logs  form  the  basis  of  the  VCR  paradigm  and
       retrospective performance analysis services common to the PCP toolkit.

       The  mandatory  argument archive is the base name for the physical files that constitute an archive.  The
       archive argument may contain strftime(3) meta-characters, which will be substituted prior to creating the
       archive files.  When pmlogger is run as a service (see pmlogger_daily(1)), the standard archive base name
       template is %Y%m%d.%H.%M.

       The -V option specifies the version for the archive that is generated.  By default  the  archive  version
       $PCP_ARCHIVE_VERSION  (set to 3 in current PCP releases) is used, and the only values currently supported
       for version are 2 or 3.

       Unless directed to another host by the -h option or when directly using PMDAs via the -o option, pmlogger
       will contact the Performance Metrics Collector Daemon (PMCD) on the local host and use that as the source
       of the metric values to be logged.

       To support the required flexibility and control over what is  logged  and  when,  pmlogger  maintains  an
       independent  two  level  logging  state  for  each  instance  of  each  performance metric.  At the first
       (mandatory) level, logging is allowed to be on (with an associated interval between samples), or  off  or
       maybe.   In  the latter case, the second (advisory) level logging is allowed to be on (with an associated
       interval between samples), or off.

       The mandatory level allows universal specification that some metrics must  be  logged,  or  must  not  be
       logged.   The  default state for all instances of all metrics when pmlogger starts is mandatory maybe and
       advisory off.

       Use pmlc(1) to interrogate and change the logging state once pmlogger is running.

       If a metric's state is mandatory (on or off) and a request is made to change it to mandatory  maybe,  the
       new state is mandatory maybe and advisory off.  If a metric's state is already advisory (on or off) and a
       request is made to change it to mandatory maybe, the current state is retained.

       It  is  not  possible  for  pmlogger  to log specific instances of a metric and all instances of the same
       metric concurrently.  If specific instances are being logged and a request to log all instances is  made,
       then  all  instances  of  the  metric  will be logged according to the new request, superseding any prior
       logging request for the metric.  A request to log all instances of a metric will supersede  any  previous
       request  to  log  all  instances.  A request to log specific instances of a metric when all instances are
       already being logged is refused.  To do this one must turn off logging for all instances  of  the  metric
       first.   In  each  case,  the validity of the request is checked first; for example a request to change a
       metric's logging state to advisory on when it is currently  mandatory  off  is  never  permitted  (it  is
       necessary to change the state to mandatory maybe first).

       Optionally,  each  system  running pmcd(1) may also be configured to run a ``primary'' pmlogger instance.
       This  pmlogger  instance  is  launched  by  $PCP_RC_DIR/pmlogger,  and   is   affected   by   the   files
       $PCP_SYSCONF_DIR/pmlogger/control, $PCP_SYSCONF_DIR/pmlogger/control.d/*, (use chkconfig(8), systemctl(1)
       or   similar   platform-specific  commands  to  activate  or  disable  the  primary  pmlogger  instance),
       $PCP_SYSCONFIG_DIR/pmlogger    (environment    variable    settings    for    the    primary    pmlogger)
       $PCP_SYSCONF_DIR/pmlogger/pmlogger.options  (command  line  options  passed  to the primary pmlogger) and
       $PCP_VAR_DIR/config/pmlogger/config.default (the default  initial  configuration  file  for  the  primary
       pmlogger).

       The  primary  pmlogger  instance  is  identified  by the -P option.  There may be at most one ``primary''
       pmlogger instance on each system.  The primary pmlogger instance (if any) must be  running  on  the  same
       host as the pmcd(1) to which it connects (if any), so the -h and -P options are mutually exclusive.

       Logging  of  some  metrics  is possible even in the absence of a local pmcd(1), using the "local context"
       mode of operation.  This is activated using the -o option, and causes pmlogger to make use of  local  DSO
       PMDAs  instead of communicating with pmcd(1).  When operating using a local context, the -K option may be
       used to control the DSO PMDAs that should be made accessible.  The spec argument conforms to  the  syntax
       described in pmSpecLocalPMDA(3).  More than one -K option may be used.

       When  launched as a non-primary instance, pmlogger will exit immediately if the configuration file causes
       no metric logging to be scheduled.  The -L option overrides  this  behavior,  and  causes  a  non-primary
       pmlogger instance to ``linger'', presumably pending some future dynamic re-configuration and state change
       via  pmlc(1).  pmlogger will also linger without the -L option being used if all the metrics to be logged
       are logged as once only metrics.  When the once only metrics have been logged, a warning message will  be
       generated stating that the event queue is empty and no more events will be scheduled.

       By default all diagnostics and errors from pmlogger are written to the file pmlogger.log in the directory
       where pmlogger is launched.  The -l option may be used to override the default behavior.  If the log file
       cannot  be  created  or is not writable, output is written to standard error instead.  If the logfile for
       the -l option is "-" (i.e.  -l-) then log messages are written to the standard output stream.   This  can
       be particularly useful when running pmlogger manually, rather than as a service daemon.

       The -N option directs pmlogger to notify a service manager, typically systemd(1), when it has started and
       is  about to begin writing PCP archives.  This option would only normally be used when pmlogger is run as
       a   daemon   service   under   the   control   of   a   service   manager.    For   more   details,   see
       __pmServerNotifyServiceManagerReady(3)  and  systemd(1).   On platforms that do not use a service manager
       that supports notifications, the -N option is basically a no-op.

       If specified, the -s option instructs pmlogger to terminate after a certain size  in  records,  bytes  or
       time  units  has  been accumulated.  If endsize is an integer then endsize records will be written to the
       archive.  If endsize is an integer suffixed by b or bytes then endsize bytes of the archive data will  be
       written  out  (note,  however, that archive record boundaries will not be broken and so this limit may be
       slightly surpassed).  Other viable file size units include: K, Kb, KiB, Kbyte, Kilobyte for kilobytes and
       M, Mb, MiB, Mbyte, Megabyte for megabytes and G, Gb, GiB, Gbyte, Gigabyte for gigabytes.  These units may
       be optionally suffixed by an s and may be of mixed case.  Alternatively endsize may be an  integer  or  a
       floating  point  number  suffixed using a time unit as described in PCPIntro(1) for the interval argument
       (to the standard PCP -t command line option).
       Some examples of different formats:
          -s 100
          -s 100bytes
          -s 100K
          -s 100Mb
          -s 10Gbyte
          -s 10mins
          -s 1.5hours
       The default is for pmlogger to run forever.

       The -r option causes the size of the physical record(s) for  each  group  of  metrics  and  the  expected
       contribution of the group to the size of the PCP archive for one full day of collection to be reported in
       the  log  file.   This  information  is reported the first time each group is successfully written to the
       archive.

       The -U option specifies the user account under which to run pmlogger.  The default is  the  current  user
       account  for  interactive  use.   When run as a daemon, the unprivileged "pcp" account is used in current
       versions of PCP, but in older versions the superuser account ("root") was used by default.

       The archive is potentially a multi-volume data set, and the -v option causes  pmlogger  to  start  a  new
       volume after a certain size in records, bytes, or time units has been accumulated for the current volume.
       The  format of this size specification is identical to that of the -s option (see above).  The default is
       for pmlogger to create  a  single  volume  archive.   Additional  volume  switches  can  also  be  forced
       asynchronously  by  either  using  pmlc(1)  or  sending pmlogger a SIGHUP signal (see below).  Note, if a
       scheduled volume switch is in operation due to the -v option, then its counters will be  reset  after  an
       asynchronous switch.

       Independent  of  any  -v  option,  each  volume  of  an archive is limited to no more than 2^31 bytes, so
       pmlogger will automatically create a new volume for the archive before this limit is reached.

       Normally pmlogger operates on the distributed Performance Metrics Name Space (PMNS), however  if  the  -n
       option is specified an alternative local PMNS is loaded from the file pmnsfile.

       Under  normal  circumstances, pmlogger will run forever (except for a -s option or a termination signal).
       The -T option may be used to limit the  execution  time  using  the  format  of  time  as  prescribed  by
       PCPIntro(1).   The  time  is interpreted within the time zone of the PMCD server, unless the -y option is
       given, within which case the time zone at this logger host is used.
       Some examples of different formats:
          -T 10mins
          -T '@ 11:30'
       From this it can be seen that -T 10mins and -s 10mins perform identical actions.

       Alternatively, pmlogger runtime may be limited to the lifetime of another process  by  using  the  -p  or
       --PID  option  to  nominate the PID of the process of interest.  In this case the pmlogger will exit when
       the other process no longer exists.

       When pmlogger receives a SIGHUP signal, the current volume of the archive is closed, and a new volume  is
       opened.   This  mechanism  (or the alternative mechanism via pmlc(1)) may be used to manage the growth of
       the archive files - once a log volume is closed, that file may be  archived  without  ill-effect  on  the
       continued operation of pmlogger.  See also the -v option above.

       When pmlogger receives a SIGUSR2 signal, the current archive is closed, and a new archive is opened.  For
       this  to  succeed,  the  original  archive  argument  must  include  strftime(3)  meta  characters  (e.g.
       %Y%m%d.%H.%M), otherwise pmlogger will exit because the archive files will  already  exist  and  pmlogger
       will  not  over-write  existing archive files.  Note that SIGUSR2 triggers pmlogger to re-exec itself and
       re-parse all original arguments.  This means that any relative time limits  placed  on  it's  termination
       time  or  sampling  limit  are  reset and begin again.  This only affects relative termination times, not
       absolute times e.g.  -T 5s is affected, but -T 5pm is not.

       Historically the buffers for the current archive may be flushed  to  disk  using  the  flush  command  of
       pmlc(1),  or  by  using  the  -u  option.   The  current version of pmlogger and the libpcp routines that
       underpin pmlogger unconditionally use unbuffered writes and a single fwrite(3) for  each  logical  record
       written, and so ``flushing'' does not force any additional data to be written to the file system.  The -u
       option and the pmlc(1) flush command are retained for backwards compatibility.

       When  launched  with  the  -x  option,  pmlogger  will  accept  asynchronous control requests on the file
       descriptor fd.  This option is only expected to be used  internally  by  PCP  applications  that  support
       ``live record mode''.

       The  -m option allows the string note to be appended to the map file for this instance of pmlogger in the
       $PCP_TMP_DIR/pmlogger directory.  This is currently used internally to document the file descriptor  (fd)
       when  the  -x option is used, or to indicate that this pmlogger instance was started under the control of
       pmlogger_check(1), (-m pmlogger_check) or was re-exec'd (see execvp(3)) due to  a  SIGUSR2  signal  being
       recieved as described above (-m reexec).

       The  -H  option allows the hostname written into the archive label to be overridden.  This mirrors the -H
       option of pmcd(1) , but allows it to be specified on the pmlogger  process.   Without  this  option,  the
       value returned from the logged pmcd(1) is used.

       The -C option will cause the configuration file to be parsed and pmlogger will then exit without creating
       an  output  archive,  so  when  -C  is specified, the archive command line argument is not required.  Any
       errors in the configuration file are reported.

       The -d or --directory option may be used to specify the directory where the archive  should  be  created.
       directory  may include sh(1) metacharacters, like $(...)  or `...` or $var and pmlogger will expand these
       to produce a final directory path.  The resultant path must be absolute, not relative.  The -d option  is
       intended  primarily  for  use  by  pmlogger_check(1) and normal users would not typically need to use the
       option, as the directory for archive is either implied by archive if  it  contains  directory  components
       else the current directory by default.

CONFIGURATION FILE SYNTAX

       The  configuration  file may be specified with the -c option.  If it is not, configuration specifications
       are read from standard input.

       If conffile does not exist, then a search is made in the  directory  $PCP_VAR_DIR/config/pmlogger  for  a
       file  of  the  same  name,  and  if  found that file is used, e.g. if config.mumble does not exist in the
       current  directory  and  the  file  $PCP_VAR_DIR/config/pmlogger/config.mumble  does   exist,   then   -c
       config.mumble and -c $PCP_VAR_DIR/config/pmlogger/config.mumble are equivalent.

       The syntax for the configuration file is as follows.

       1.   Words are separated by white space (space, tab or newline).

       2.   The symbol ``#'' (hash) introduces a comment, and all text up to the next newline is ignored.

       3.   Keywords (shown in bold below) must appear literally (i.e. in lower case).

       4.   Each specification begins with the optional keyword log, followed by one of the states mandatory on,
            mandatory off, mandatory maybe, advisory on or advisory off.

       5.   For  the  on  states,  a  logging interval must follow using the syntax ``once'', or ``default'', or
            ``every N timeunits'', or simply ``N timeunits'' - N is an unsigned integer, and timeunits is one of
            the keywords msec, millisecond, sec, second, min, minute, hour or the plural  form  of  one  of  the
            above.
            Internal  limitations require the interval to be smaller than (approximately) 74 hours.  An interval
            value of zero is a synonym for once.  An interval of  default  means  to  use  the  default  logging
            interval  of  60  seconds;  this  default  value may be changed to interval with the -t command line
            option.

            The interval argument follows the syntax described in PCPIntro(1), and in the simplest form  may  be
            an unsigned integer (the implied units in this case are seconds).

       6.   Following the state and possible interval specifications comes a ``{'', followed by a list of one or
            more  metric  specifications and a closing ``}''.  The list is white space (or comma) separated.  If
            there is only one metric specification in the list, the braces are optional.

       7.   A metric specification consists of a metric name optionally followed by a  set  of  instance  names.
            The  metric name follows the standard PCP naming conventions, see PMNS(5), and if the metric name is
            a non-leaf node in the PMNS (see PMNS(5)), then pmlogger will recursively descend the PMNS and apply
            the logging specification to all descendent metric names that are leaf nodes in the PMNS.   The  set
            of  instance  names  is a ``['', followed by a list of one or more space (or comma) separated names,
            numbers or strings, and a closing ``]''.  Elements in the list that are numbers are  assumed  to  be
            internal  instance identifiers, other elements are assumed to be external instance identifiers - see
            pmGetInDom(3) for more information.

            If no instances are given, then the logging  specification  is  applied  to  all  instances  of  the
            associated metric.

       8.   There may be an arbitrary number of logging specifications.

       9.   As  of PCP version 4.0 and later, any metric name specification that does not resolve to a leaf node
            in the PMNS is added to an internal list of possible dynamic subtree roots.  PMDAs  can  dynamically
            create  new metrics below a dynamic root node in their PMNS, and send a notification to clients that
            the PMNS has changed, see pmdaExtSetFlags(3) and in particular the METRIC CHANGES  section  for  API
            details.   This mechanism is currently supported by pmdaopenmetrics(1) and pmdammv(1).  When a fetch
            issued by pmlogger returns with the PMDA_EXT_NAMES_CHANGE  flag  set,  pmlogger  will  traverse  the
            internal  list  of  possible  dynamic  subtree  nodes  and dynamically discover any new metrics.  In
            effect, as of PCP version 4.0 and later, pmlogger can be configured to dynamically log  new  metrics
            that appear in the future, after the configuration file is initially parsed.

       10.  Following  all  of  the  logging  specifications,  there  may be an optional access control section,
            introduced by the literal token [access].  Thereafter  come  access  control  rules  that  allow  or
            disallow operations from particular hosts or groups of hosts.

            The  operations may be used to interrogate or control a running pmlogger using pmlc(1) and fall into
            the following classes:

            enquire        interrogate the status of pmlogger and the metrics it is logging
            advisory       Change advisory logging.
            mandatory      Change mandatory logging.
            all            All of the above.

            Access control rules are of the form ``allow hostlist : operationlist ;'' and ``disallow hostlist  :
            operationlist ;''.

            The hostlist follows the syntax and semantics for the access control mechanisms used by PMCD and are
            fully  documented  in  pmcd(1).   An  operationslist  is  a  comma  separated list of the operations
            advisory, mandatory, enquire and all.

            A missing [access] section allows all access and is equivalent to allow * : all;.

       The configuration (either from standard input or conffile) is initially  scanned  by  pmcpp(1)  with  the
       options -rs and -I $PCP_VAR_DIR/config/pmlogger.  This extends the configuration file syntax with include
       file processing (%include), a common location to search for include files ($PCP_VAR_DIR/config/pmlogger),
       macro  definitions  (%define),  macro  expansion  (%name  and %{name}) and conditional inclusion of lines
       (%ifdef name ... %else ... %endif and %ifndef name ... %else ... %endif).

OPTIONS

       The available command line options are:

       -c conffile, --config=conffile
            Specify the conffile file to use.

       -C, --check
            Parse configuration and exit.

       -h host, --host=host
            Fetch performance metrics from pmcd(1) on host, rather than from the default localhost.

       -H hostname, --labelhost=hostname
            Specify the hostname to use instead of the one returned by pmcd(1).

       -I version, --pmlc-ipc-version=version
            Normally, pmlogger and pmlc(1) will autonegotiate a mutually acceptable version  for  their  private
            IPC  channel.   Use -I to force pmlogger to offer (at most) version as the version to be used.  This
            option may be required if pmlogger needs to be managed by an older version of pmlc(1) that fails  to
            autonegotiate correctly.

       -K spec, --spec-local=spec
            When  fetching  metrics  from a local context (see -o), the -K option may be used to control the DSO
            PMDAs that should be made accessible.  The  spec  argument  conforms  to  the  syntax  described  in
            pmSpecLocalPMDA(3).  More than one -K option may be used.

       -l logfile, --log=logfile
            Write all diagnostics to logfile instead of the default pmlogger.log.

       -L, --linger
            Run even if not the primary logger instance and nothing to log.

       -m note, --note=note
            Append note to the port map file for this instance.

       -n pmnsfile, --namespace=pmnsfile
            Load an alternative Performance Metrics Name Space (PMNS(5)) from the file pmnsfile.

       -N, --notify
            Notify service manager such as systemd(1) as needed.

       -o, --local-PMDA
            Use a local context to collect metrics from DSO PMDAs on the local host without PMCD.  See also -K.

       -p PID, --PID=PID
            Log specified metrics for the lifetime of the pid PID.

       -P, --primary
            Run as primary logger instance.  See above for more detailed description of this.

       -r, --report
            Report record sizes and archive growth rate.

       -s endsize, --size=endsize
            Terminate after archive size exceeds endsize.

       -t interval, --interval=interval
            Specify the logging interval.  The default value is 60 seconds.  Please refer to the ENVIRONMENT and
            FILES  sections  below  regarding  the  PMLOGGER_INTERVAL environment variable and its impact on the
            default logging interval.

       -T endtime, --finish=endtime
            Specify the endtime when to end logging.

       -u   Use unbuffered output.  This is the default (so this option does nothing).

       -U username, --username=username
            When in daemon mode, run as user username.

       -v volsize, --volsize=volsize
            Switch volumes after reaching archive volume size volsize.

       -V version, --version=version
            Specify archive version.  The default and the only accepted value is 2.

       -x fd
            Allow asynchronous control requests on the file descriptor fd.

       -y   Use local timezone instead of the timezone from the pmcd(1) host.

       -?, --help
            Display usage message and exit.

EXAMPLES

       For each PCP utility, there is a sample pmlogger configuration file that  could  be  used  to  create  an
       archive  suitable  for replaying with that tool (i.e. includes all of the performance metrics used by the
       tool).     For    a    tool    named    foo     this     configuration     file     is     located     in
       $PCP_VAR_DIR/config/pmlogger/config.foo.

       The  following  is  a simple default configuration file for a primary pmlogger instance, and demonstrates
       most of the capabilities of the configuration specification language.

            log mandatory on once { hinv.ncpu hinv.ndisk }
            log mandatory on every 10 minutes {
                disk.all.write
                disk.all.read
                network.interface.in.packets [ "et0" ]
                network.interface.out.packets [ "et0" ]
                nfs.server.reqs [ "lookup" "getattr" "read" "write" ]
            }

            log advisory on every 30 minutes {
                environ.temp
                pmcd.pdu_in.total
                pmcd.pdu_out.total
            }

            %include "macros.default"

            %ifdef %disk_detail
            log mandatory on %disk_detail_freq {
                disk.dev
            }
            %endif

            [access]
            disallow * : all except enquire;
            allow localhost : mandatory, advisory;

HOSTNAME CHANGES

       The hostname of the PMCD that is providing metrics to pmlogger is used in several ways.

       PMCD's hostname (or the argument from the -H option) is included in the archive label and may be used  to
       ensure  that  subsequent  operations  on  multiple  archives,  e.g.  pmlogextract(1), are only applied to
       archives from the same host.

       For pmlogger instances using a local  PMCD  that  are  launched  and  managed  by  pmlogger_check(1)  and
       pmlogger_daily(1), (or the systemd(1) or cron(8) services that use these scripts), the local hostname may
       also  be  used  to  construct the name of a directory where all the archives for the one host are stored,
       e.g. $PCP_ARCHIVE_DIR/<hostname>.

       And PMCD's hostname is also stored in the archive via the pmcd.pmlogger.hostname metric that is  used  as
       part  of  the  checks  to  ensure  that there is continuity of performance data after the nightly archive
       rotation by pmlogger_daily(1).

       The hostname of the PMCD host may change during boot time when the system transitions  from  a  temporary
       hostname to a persistent hostname, or by explicit administrative action anytime after the system has been
       booted.   When  this  happens,  pmlogger  may  need  to take special action, specifically if the pmlogger
       instance was launched from pmlogger_check(1) or pmlogger_daily(1), then pmlogger must exit.  Under normal
       circumstances systemd(1) or cron(8) will launch a new pmlogger shortly thereafter, and this new  pmlogger
       instance will be operating in the context of the new hostname for the host where PMCD is running.

DIAGNOSTICS

       The  archives  are  sufficiently  precious  that pmlogger will not truncate an existing physical file.  A
       message of the form
        ...: "foo.index" already exists, not over-written
        ...: File exists
       indicates this situation has arisen.  You must explicitly remove the files and launch pmlogger again.

       There may be at most one primary pmlogger instance per monitored  host;  attempting  to  bend  this  rule
       produces the error:
        pmlogger: there is already a primary pmlogger running

       Various other messages relating to the creation and/or deletion of files in $PCP_TMP_DIR/pmlogger suggest
       a permission problem on this directory, or some feral files have appeared therein.

FILES

       archive.meta
            metadata (metric descriptions, instance domains, etc.) for the archive

       archive.0
            initial volume of metrics values (subsequent volumes have suffixes 1, 2, ...)

       archive.index
            temporal index to support rapid random access to the other files in the archive

       $PCP_TMP_DIR/pmlogger
            pmlogger  maintains  the  files  in this directory as the map between the process id of the pmlogger
            instance and the IPC port that may be used to control each pmlogger instance (as used by pmlc(1))

       $PCP_VAR_DIR/config/pmlogger/config.default
            default configuration file for the primary logger instance launched from $PCP_RC_DIR/pmlogger

       $PCP_VAR_DIR/config/pmlogger/config.*
            assorted configuration files suitable for creating logs that may be subsequently replayed  with  the
            PCP visualization and monitoring tools

       $PCP_ARCHIVE_DIR/<hostname>
            Default  directory  for  PCP  archive  files  for  performance metric values collected from the host
            <hostname>.

       $PCP_SYSCONFIG_DIR/pmlogger
            additional environment variables that will be set when the primary pmlogger instance executes.  Only
            settings of the form "PMLOGGER_VARIABLE=value" will be honoured.

       ./pmlogger.log
            (or    $PCP_ARCHIVE_DIR/<hostname>/pmlogger.log    when    started    automatically    by     either
            $PCP_RC_DIR/pmlogger or one of the pmlogger(1) monitoring scripts such as pmlogger_check(1))
            all messages and diagnostics are directed here

ENVIRONMENT

       Normally pmlogger creates a socket to receive control messages from pmlc(1) on the first available TCP/IP
       port  numbered  4330  or  higher.   The  environment  variable  PMLOGGER_PORT  may  be used to specify an
       alternative starting port number.

       If set to the value 1, the PMLOGGER_LOCAL environment variable will cause pmlogger to run in a localhost-
       only mode of operation, where it binds only to the loopback interface.

       The PMLOGGER_REQUEST_TIMEOUT variable may be set by applications such as pmlc(1) to specify a timeout  in
       seconds  for  connection  requests  to  the  pmlogger  control  port.   If not set, connections may block
       indefinitely.  This variable would not normally be set by pmlogger itself.

       The PMLOGGER_MAXPENDING variable can be set to indicate the maximum length to which the queue of  pending
       pmlc connections may grow.

       The  default  sampling  interval used by pmlogger can be set using the PMLOGGER_INTERVAL variable (if not
       set, 60 seconds will be used).  Both the command line and  directives  in  the  configuration  file  will
       override this value.  It is an integer in units of seconds.

       On  platforms  using  systemd(1), and when the -N option is given, the NOTIFY_SOCKET environment variable
       would normally be set by the service manager prior to launching pmlogger.

PCP ENVIRONMENT

       Environment variables with the prefix PCP_ are used to parameterize the file and directory names used  by
       PCP.   On  each  installation, the file /etc/pcp.conf contains the local values for these variables.  The
       $PCP_CONF variable may be used to specify an alternative configuration file, as described in pcp.conf(5).

SEE ALSO

       PCPIntro(1),  pmcd(1),  pmdumplog(1),  pmlc(1),   pmlogger_check(1),   pmlogger_daily(1),   systemctl(1),
       systemd(1), execvp(3), PMAPI(3), __pmServerNotifyServiceManagerReady(3), pmSpecLocalPMDA(3), strftime(3),
       pcp.conf(5), pcp.env(5), pmlogger(5), PMNS(5), chkconfig(8) and cron(8).

Performance Co-Pilot                                   PCP                                           PMLOGGER(1)