Provided by: nfdump_1.7.3-1build2_amd64 bug

NAME

       nfpcapd - pcap capture to netflow daemon

SYNOPSIS


       nfpcapd [options]

DESCRIPTION

       nfpcapd  is  the  pcap  capture daemon of the nfdump tools. It reads network packets from an interface or
       from a file and directly creates nfdump records. Nfdump records are written either locally to a directory
       in the same format as nfcapd, or can be forwarded to a nfcapd collector somewhere else  in  the  network.
       Nfpcapd  is  nfcapd's  pcap brother and shares many options and generates the same type of files. nfpcapd
       likewise creates, rotates and stores files. See also nfpcap(1) for more information on common option.

       nfpcapd optionally also stores pcap traffic data in separate files and uses the same rotation interval as
       for the netflow data. Storing pcap traffic data file is only possible locally.

       nfpcapd is multithreaded and uses separate threads for packet, netflow and pcap processing.

OPTIONS

       -i interface
          Listen on this interface in promisc mode for packet processing.

       -r file
          Read and process packets from this file. This file is a pcap compatible file

       -s snaplen
          Limit the snaplen on collected packets. The default is 1522 bytes.  The  snaplen  needs  to  be  large
          enough to process all required protocols. The snaplen must not be smaller than 54 bytes.

       -B cachesize
          Sets  the  number of initial cache nodes required by the flow cache.  By default the cache size is set
          to 512k nodes should be fine. If the cache runs out of nodes, new nodes are dynamically added.

       -e active,inactive
          Sets the active and inactive flow expire values in s. The default is 300,60.
          Active timeout: A flow gets flushed to disk after this period even if it is still active. As a rule of
          thumb, it should correspond with the -t rotation value, in order to reflect continuous traffic in  the
          flow files.
          Inactive  timeout:  A  flow  gets  flushed to disk after being inactive for this number of seconds. It
          frees up node resources.
          On busy networks these values can be set to more aggressive timeouts.

       -I IdentString ( capital letter i )
          Specifies an ident string, which describes the source e.g. the name of the  interface  or  host.  This
          string is put into the stat record to identify the source. Default is 'none'. Same is nfcapd(1)

       -l flowdir ( letter ell )
          Specifies  the  base  directory  to store the flow files.  If a sub hierarchy is specified with -S the
          final directory is concatenated to base_directory/sub_hierarchy.

       -p pcapdir
          Store network packets in pcap compatible files in this directory and rotate files the same as the flow
          files. Sub hierarchy directories are applied likewise.

       -H <host[/port]>
          Send nfdump records to a remote nfcapd collector. Default port is 9995.

       -S <num>
          Allows to specify an additional directory sub hierarchy to store the data files. The default is 0,  no
          sub  hierarchy,  which means the files go directly in the base directory (-l). The base directory (-l)
          is concatenated with the specified sub hierarchy format to form the final data directory.  For a  full
          list of hierarchies see nfcapd(1).

       -t interval
          Specifies  the  time  interval  in  seconds  to  rotate files. The default value is 300s ( 5min ). The
          smallest interval can be set to 2s. The intervals are in sync with wall clock.

       -P pidfile
          Specify name of pidfile. Default is no pidfile.

       -D Daemon mode: fork to background and detach from terminal.  Nfpcapd terminates on signal TERM, INT  and
          HUP.

       -E Verbose  flow  printing.  Print  flows on stdout, when flushed to disk.  Use verbose printing only for
          debugging purpose in order to see if  your  setup  works.  Running  nfpcapd  in  verbose  mode  limits
          processing bandwidth!

       -u userid
          Change  to  the  user  userid as soon as possible. Only root is allowed to use this option. Uid/Gid is
          switched after opening the reading device.

       -g groupid
          Change to the group groupid as soon as possible. Only root is allowed  use  this  option.  Uid/Gid  is
          switched after opening the reading device.

       -o option[,option]
          Adds options to nfpcapd. Two options are available:
          fat       Add Mac addresses, optional Vlan and MPLS labels.
          payload   Add the payload bytes of the first packet of a connection.

       -z=lzo
          Compress flows. Use fast LZO1X-1 compression in output file.

       -z=lz4
          Compress flows. Use LZ4 compression in output file.

       -z=bz2
          Compress flows. Use bz2 compression in output file. Note: not recommended while collecting

       -V Print nfpcapd version and exit.

       -h Print help text to stdout with all options and exit.

       '<filter>'
          Optional pcap compatible packet filter. The filter needs to be put within quotes.

RETURN VALUE

       Returns 0 on success, or 255 if initialization failed.

LOGGING

       nfpcapd  logs  to  syslog  with SYSLOG_FACILITY LOG_DAEMON.  For normal operation level 'error' should be
       fine.  More information is reported at level 'info'.

       A small statistic about the collected flows, as well as errors are reported at the end of every  interval
       to syslog with level 'info'.

EXAMPLES

       Read packets from interface eth0
              nfpcapd -i eth0 -j -D -l /netflow/flows -S 2 -I any -P /var/run/nfpcapd.pid

       Read packets from interface mx0 and store also packets in pcap files.
              nfpcapd -i vmx0 -j -D -l /netflow/flows -p /netflow/caps

       Send records to a remote host
              nfpcapd -i eth1 -H 192.168.200.10/12344 -D -e 60,20

NOTES

       nfpcapd can store records either locally or send it to a remote host but not both at the same time.
       If  records  are  sent  to  a remote nfcapd process, both programs nfcapd and nfpcapd must be of the same
       endian architecture (both big or little endian). nfpcapd uses netflow version 240 for sending flows.

       The flow cache is checked in regular 10s intervals and expires flows  according  to  the  expire  values.
       Expired flows are flushed and processed and nodes are freed up.

       A  smaller  snaplen may improve performance, but may result in loss of information.  The smallest snaplen
       of 54 bytes can process regular TCP/UDP/ICMP packets.  In  case  of  Vlan  or  MPLS  labels,  not  enough
       information  may be available for correct protocol decoding. Nfdump records may be incomplete and and set
       to 0.

       If IP packets are fragmented, they are reassembled  before  processing.  All  IP  fragments  need  to  be
       reassembled  in order to be passed to the next stage. If not all fragments are correctly assembled within
       15s since the first fragment arrived, all fragments are discarded.

SEE ALSO

       nfcapd(1), nfdump(1), nfexpire(1)

BUGS

       No software without bugs! Please report any bugs back to me.

                                                   2023-05-23                                         nfpcapd(1)