DESCRIPTION

       wacom is an X input driver for Wacom devices.

       The wacom driver functions as a pointer input device.

SUPPORTED HARDWARE

       This driver supports virtually all tablet devices that are supported by the Linux kernel.

       Please check https://github.com/linuxwacom for latest updates of Wacom X and kernel drivers.

DRIVER-INTERNAL DEVICE HOTPLUGGING

       Configuration  via  Section "InputDevice" is discouraged as such devices cannot be hotplugged at runtime.
       Instead users should use Section "InputClass" as in  the  example  above.  The  InputClass  section  (see
       xorg.conf.d(5))  assigns this driver for the device, the wacom driver creates multiple X devices for each
       physical device, one X device for each available tool. The  list  of  tools  is  hardware-dependent.  See
       Option Type as outlined in the CONFIGURATION DETAILS section.

       These  tool-specific devices are referred to as parent device and dependent device.  The parent device is
       the one presented by the system and the one that causes the X server  to  load  the  wacom  driver.  This
       parent  device  then  causes the automatic addition of several dependent devices. If the parent device is
       unplugged or otherwise removed, the dependent devices will be automatically removed as well.

       Dependent devices may be assigned  tool-specific  options  through  additional  InputClass  sections.  We
       recommend  that  a  MatchDriver  wacom  line  is  used in these sections in addition to the user-specific
       pattern.

       Match directives are applied by the X server before the driver is selected.  The type name of the  parent
       device  is  appended  by  the driver. It is not possible to use a MatchProduct directive to match against
       this appended type name.

CONFIGURATION DETAILS

       Please refer to xorg.conf(5) or xorg.conf.d(5) for general configuration details and for options that can
       be used with all input drivers.  This section only covers configuration details specific to this driver.

       Multiple instances of the Wacom devices can cohabit. Each device supports the following entries:

       Option "Type" "stylus"|"eraser"|"cursor"|"pad"|"touch"
           sets the type of tool the device represents. This option is mandatory.  The  core  options,  such  as
           "SendCoreEvents"  or  "AlwaysCore",  are  unnecessary in Gimp if you don't need to move system cursor
           outside of Gimp drawing area.  "pad" is for Intuos 3 or Cintiq 21UX tablet  ExpressKeys/menu  strips,
           and Graphire 4 or Bamboo tablet buttons, wheel, and/or ring.  It is required  for Intuos3,  CintiqV5,
           Graphire  4, and Bamboo if you want to use keystroke features.  "pad" is reported as a second tool in
           the driver. "touch" is for the tablet with touch support.  Right now only a few Tablet PCs have  this
           feature.

       Option "Device" "path"
           sets the path to the special file which represents serial line where the tablet is plugged.  You have
           to  specify  it for each subsection with the same value if you want to have multiple devices with the
           same tablet.  This option is mandatory only if using Section "InputDevice" for static configuration.

       Option "Suppress" "number"
           sets the position increment under which not to transmit coordinates.  This entry  must  be  specified
           only  in the first Wacom subsection if you have multiple devices for one tablet. If you don't specify
           this entry, the default value,  which is 2, will be used. To disable suppression, the entry should be
           specified as 0.  When suppress is defined,  an event will be sent only  when  at  least  one  of  the
           following conditions is met:

                   the change between the current X coordinate and the previous one is greater than suppress;

                   the change between the current Y coordinate and the previous one is greater than suppress;

                   the change between the current pressure and the previous one is greater than suppress;

                   the  change between the  current degree of rotation and the previous one of the transducer is
           greater than suppress;

                   the change between the current absolute wheel value and the  previous  one  is  equal  to  or
           greater than suppress;

                   the  change  between  the current tilt value and the previous one is equal to or greater than
           suppress (if tilt is supported);

                   relative wheel value has changed;

                   button value has changed;

                   proximity has changed.

       Option "Mode" "Relative"|"Absolute"
           sets the mode of the device.  The default value for stylus, pad and eraser  is  Absolute;  cursor  is
           Relative; touch defaults to Relative for tablets with touch pads and Absolute for touch screens.

       Option "TopX" "number"
           X coordinate of the top corner of the active zone.  Default to 0.

       Option "TopY" "number"
           Y coordinate of the top corner of the active zone.  Default to 0.

       Option "BottomX" "number"
           X coordinate of the bottom corner of the active zone.  Default to width of the tablet.

       Option "BottomY" "number"
           Y coordinate of the bottom corner of the active zone.  Default to height of the tablet.

       Option "ButtonsOnly" "on"|"off"
           disables the device's motion events.  Default to off.

       Option "ButtonM" "AC"
           reports  an  action  AC  when  button  M  is pressed,  where M is one of the device supported  button
           numbers,  it can be 1 to 32. Wacom uses a driver-internal button mapping, where any  physical  button
           appears  to  the  X  server  as  the  button specified by the ButtonM mapping. Hence, if two physical
           buttons have the same ButtonM mapping, the server will think they are the same physical button.   The
           default  action reported to the X server is mouse button M click. Because X uses buttons 4, 5, 6, and
           7 as the four scrolling directions, physical buttons 4 and higher are  mapped  to  8  and  higher  by
           default.   Only  simple  button  presses  can  be  configured  here;  for  more  complex actions, use
           xsetwacom(1).  To ignore the button click, i.e., to not report  any  button  click  event  to  the  X
           server,  use "0" or "button 0".

       Option "TPCButton" "on"|"off"
           enables  the  stylus  buttons as Tablet PC buttons. If enabled, the stylus reports button events only
           when its tip is pressed. If any button is down, pressing the tip  reports  a  button  event  for  the
           button.  Otherwise  if  no button is down, the tip reports as usual.  Default to "on" for Tablet PCs;
           "off" for all other models. Only available on the stylus tool.

       Option "Touch" "on"|"off"
           enables touch events for touch devices,  i.e., system cursor moves  when  user  touches  the  tablet.
           Default to "on" for devices that support touch; "off" for all other models.

       Option "Rotate" "CW"|"CCW"|"HALF"|"NONE"
           rotates  the  tablet  orientation counterclockwise (CCW) or clockwise (CW) or 180 degrees (HALF).  If
           you have specific tablet mappings, i.e. TopX/Y or BottomX/Y were set, the  mapping  will  be  applied
           before  rotation.  Rotation  must  be  applied  to  the  parent device (usually the stylus), rotation
           settings on in-driver hotplugged devices (see DRIVER-INTERNAL DEVICE HOTPLUGGING ) will  be  ignored.
           The default is "NONE".

       Option "PressCurve" "x1,y1,x2,y2"
           sets pressure curve by control points x1, y1, x2, and y2.  Their values are in range from 0..100. The
           pressure  curve  is interpreted as Bezier curve with 4 control points, the first and the last control
           point being fixed on the coordinates 0/0 and 100/100, respectively. The  middle  control  points  are
           adjustible  by  this  setting  and  thus  define  the shape of the curve.  The input for linear curve
           (default) is "0,0,100,100"; slightly depressed curve (firmer) might be "5,0,100,95"; slightly  raised
           curve  (softer)  might  be  "0,5,95,100".   The  pressure curve is only applicable to devices of type
           stylus or eraser, other devices do not honor this setting.

       Option "Pressure2K" "bool"
           reduces the pressure range to the range of 0 to 2048 for backwards  compatibility  with  applications
           that  have  this  range hardcoded.  See section BUGS.  This option should not be used unless the user
           runs one or more applications that rely on a hardcoded pressure range.

       Option "DebugLevel" "number"
           sets the level of debugging info for tool-specific messages.  There are 12 levels, specified  by  the
           integers  between  1 and 12.  All debug messages with a level less than or equal to the "number" will
           be logged into the Xorg log file. This option  is  only  available  if  the  driver  was  built  with
           debugging support.

       Option "CommonDBG" "number"
           sets  the level of debugging info for common (i.e. not tool-specific) code paths on the tablet. There
           are 12 levels, specified by the integers between 1 and 12. All debug messages with a level less  than
           or  equal to the "number" will be logged into the Xorg log file. This option is only available if the
           driver was built with debugging support.

       Option "GrabDevice" "bool"
           sets whether the underlying event device will be grabbed by the  driver  to  prevent  the  data  from
           leaking  to  /dev/input/mice.  When enabled, while the X server is running, no other programs will be
           able to read the event stream.  Default: "false".

       Option "CursorProx" "number"
           sets the distance at which a relative tool is  treated  as  being  out  of  proximity.   Beyond  this
           distance  the  cursor  will stop responding to tool motion. The default value for pucks is 10 (Intuos
           Pro) or 42 (Intuos/Bamboo). The default value for pens is 30.

       Option "RawSample" "number"
           Set  the  sample  window  size (a sliding average sampling window) for incoming input tool  raw  data
           points.  Default:  4, range of 1 to 20.

       Option "Serial" "number"
           sets  the  serial number associated with the physical device. This allows to have multiple devices of
           the same type (i.e. multiple pens). This option is only available on wacom V devices  (Intuos  series
           and  Cintiq  21U).   To  see  which  serial  number  belongs to a device, you need to run the utility
           program, xsetwacom, which comes with linuxwacom package.

       Option "ToolSerials" "number[,type[,label]][;...]"
           sets the list of serial numbered devices that need to be hotplugged for a physical device. The 'type'
           option may be any of "pen", "airbrush", "artpen", or "cursor".  This  option  is  only  available  on
           wacom  V  devices  which  are  capable  of reporting a serial number. To see if a connected device is
           supported, or to identify which serial number belongs to a  device,  you  need  to  run  the  utility
           program, xsetwacom, that comes with this driver. In layman's terms, this option will add additional X
           devices  for  this specific tool's tip (and eraser, if applicable).  This is useful for programs like
           gimp (which remembers tools based on the X device) to recall additional drawing tool  selections  for
           an airbrush+eraser, art pen, extra pen, etc.

       Option "Threshold" "number"
           sets  the  pressure threshold used to generate a button 1 events of stylus.  The threshold applies to
           the normalised pressure range of [0..2048].  The default is 27.

       Option "Gesture" "bool"
           Enable or disable multi-finger in-driver gesture support on  the  device.  Default:  off  unless  the
           tablet  supports  multi-touch.  Note  that disabling this option may allow the desktop environment to
           detect multi-finger gestures instead.

       Option "ZoomDistance" "number"
           If Option "Gesture" is enabled, this option specifies the minimum movement  distance  before  a  zoom
           gesture is recognized.

       Option "ScrollDistance" "number"
           If  Option  "Gesture" is enabled, this option specifies the minimum movement distance before a scroll
           gesture is recognized.

       Option "TapTime" "number"
           If Option "Gesture" is enabled, this option determines the maximum  time  of  a  touch  event  to  be
           recognized  as tap. A press and release event shorter than TapTime generates button press and release
           events. Presses longer than TapTime do not generate button events, only motion events.

       Option "PressureRecalibration" "bool"
           Allows to disable pressure recalibration. Default: true.  If the initial pressure of a device is != 0
           the driver recalibrates the pressure range. This is to account for worn out devices.  The downside is
           that when the user hits the tablet very hard the initial pressure reading may be unequal to zero even
           for a perfectly good pen. If the consecutive pressure  readings  are  not  higher  than  the  initial
           pressure  by  a  threshold  no  button  event  will  be generated.  This option allows to disable the
           recalibration.

       Option "PanScrollThreshold" "number"
           Specifies the distance the pen must move (in tablet units) before a scroll event  is  generated  when
           using  the  "pan"  action.  Smaller  values  will require less distance and be more sensitive. Larger
           values will require more distance and be less sensitive.  Default: 1300 or 2600 depending  on  tablet
           resolution (corresponds to 13 mm of distance).

       Option "SmoothPanscrollingEnabled" "bool"
           Allows  to disable smooth panscrolling. Default: true.  If disabled, panscrolling sends legacy button
           events instead.  This option exists for backwards  compatibility  with  applications  that  have  the
           number  of  axes on a device limited to 6.  See section BUGS for more details. This option should not
           be used unless the user runs one or more applications that do not support more than six axes.

TOUCH GESTURES

   Single finger (1FG)
       Left click: tap, actual click happens after TapTime period elapses.

       Left click drag: tap to select, quickly (within  TapTime  period)  touch  selection  again.   Then  drag.
       Available on touchpads, e.g. BambooPT, not touchscreens.

   Two finger (2FG)
       Right click: one finger down + tap second finger

       Vertical scroll: two fingers side by side (in any orientation) moving vertically with constant separation
       initiates a vertical scroll.  By driver default a gesture up results in a scroll down event (the document
       moves up) and a gesture down results in a scroll up event (moving the document down).

       Horizontal  scroll:  two fingers side by side held at a constant distance moving horizontally initiates a
       horizontal scroll.  A gesture to the left results in a scroll right event (the document moves left) and a
       gesture right results in a scroll left event (moving the document right).

       Zoom in: two separated fingers side by side, bring together i.e. pinch.

       Zoom out: two fingers side by side, spread.  Not all applications support zoom.

BUGS

   Pressure range increase leads to unexpected behavior
       In version 0.34, the driver's pressure range increased from 2048 steps to 65536 steps. The pressure  axis
       range  is  advertised through the X Input Protocol but some applications have the previous pressure range
       hardcoded and cannot handle pressure values above 2048. This is an application  bug  but  for  backwards-
       compatibility  with  such applications, this driver provides the Pressure2K option to reduce the range to
       2048 steps. Note that this setting applies to the device. Once applied, all  applications  will  see  the
       reduced pressure range. It is not possible to provide this setting on a per-application basis.

   Smooth panscrolling exceeds the axis limits
       In  version  1.2.0,  the  driver's  support  for smooth panscrolling added two axes to the stylus device,
       bringing the total axis count to eight. The number of axes is advertised through the X Input Protocol but
       some applications (notably GIMP 2.xx) cannot handle more than six axes. This is an  application  bug  but
       for  backwards-compatibility  with  such applications, this driver provides the SmoothPanscrollingEnabled
       option to disable this feature and thus limit the axis count to six. Note that this  setting  applies  to
       the  device. Once applied, the driver will not send smooth panscroll events at all. It is not possible to
       provide this setting on a per-application basis.

SEE ALSO

       Xorg(1), xorg.conf(5), xorg.conf.d(5), X(7)

       More information is available at https://github.com/linuxwacom/xf86-input-wacom

AUTHORS

       Peter   Hutterer   <peter.hutterer@who-t.net>,   Ping   Cheng    <pingc@wacom.com>,    Frederic    Lepied
       <lepied@xfree86.org>, John E. Joganic <jej@j-arkadia.com>, Magnus Vigerlöf <Magnus.Vigerlof@ipbo.se>

X Version 11                                 xf86-input-wacom 1.2.3                                     WACOM(4)