Provided by: pcp_6.3.3-1_amd64 

NAME
pmdabind2 - BIND performance metrics domain agent (PMDA)
DESCRIPTION
This PMDA extracts performance data from BIND (Berkeley Internet Name Domain). It enables collection of
most of the statistics metrics from the Bind server version 9 or later, which includes:
• overall memory statistics
• overall per-query statistics (general queries, EDNS/truncated responses, Update/Notify/AXFR/IXFR
messages)
• overall error statistics (Rejected, SERVFAIL, Update/XFR failures ...)
• overall statistics per transport protocol, EDNS and per version of IP protocol
• resolver statistics (successes, errors, round-trip times in several ranges)
• detailed per-socket statistics with respect to the transport protocol and IP version including errors
• detailed per-file-descriptor statistics including errors
The PMDA performs per-second collection of the whole data set (148 metrics on the test environment) with
modest requirements (2% CPU usage on Intel i7-4700MQ @2.4 GHz, cca 30 MB RAM).
If more than 1 requests/sec is performed, the memoized values are used so that the statistics interface
of the Bind server does not get overloaded.
INSTALLATION
Configure BIND to export XML statistics via its REST interface. This requires BIND configuration to
enable statistics exporting locally (at least).
statistics-channels {
inet 127.0.0.1 port 8080 allow { 127.0.0.1; };
}
options { zone-statistics yes; }
# ./Install
The hostname (localhost), port (8080 above) and other configuration information must be specified in both
the BIND configuration file as well as the $PCP_PMDAS_DIR/bind2/bind2.conf file.
# cd $PCP_PMDAS_DIR/bind2
# [ edit bind2.conf ]
host=localhost.localdomain:8080
Once this is setup, you can access the names and values for the bind2 performance metrics by doing the
following as root:
# cd $PCP_PMDAS_DIR/bind2
# ./Install
To uninstall, the following must be done as root:
# cd $PCP_PMDAS_DIR/bind2
# ./Remove
pmdabind2 is launched by pmcd(1) and should never be executed directly. The Install and Remove scripts
notify pmcd(1) when the agent is installed or removed.
FILES
$PCP_PMDAS_DIR/bind2/bind2.conf
mandatory configuration file listing monitored bind2 instances
$PCP_PMDAS_DIR/bind2/Install
installation script for the pmdabind2 agent
$PCP_PMDAS_DIR/bind2/Remove
undo installation script for the pmdabind2 agent
$PCP_LOG_DIR/pmcd/bind2.log
default log file for error messages from pmdabind2
PCP ENVIRONMENT
Environment variables with the prefix PCP_ are used to parameterize the file and directory names used by
PCP. On each installation, the file /etc/pcp.conf contains the local values for these variables. The
$PCP_CONF variable may be used to specify an alternative configuration file, as described in pcp.conf(5).
SEE ALSO
PCPIntro(1), pmcd(1), pmdanamed(1), named.conf(5) and named(8).
Performance Co-Pilot PCP PMDABIND2(1)