NAME
       vendstat - query InfiniBand vendor specific functions
SYNOPSIS
       vendstat [options] <lid|guid>
DESCRIPTION
       vendstat uses vendor specific MADs to access beyond the IB spec vendor specific functionality. Currently,
       there is support for Mellanox InfiniSwitch-III (IS3) and InfiniSwitch-IV (IS4).
OPTIONS
       -N     show IS3 or IS4 general information.
       -w     show IS3 port xmit wait counters.
       -i     show IS4 counter group info.
       -c <num,num>
              configure IS4 counter groups.
              Configure  IS4  counter  groups  0  and 1. Such configuration is not persistent across IS4 reboot.
              First number is for counter group 0 and second is for counter group 1.
              Group 0 counter config values:
       ::
                 0 - PortXmitDataSL0-7 1 - PortXmitDataSL8-15 2 - PortRcvDataSL0-7
              Group 1 counter config values:
       ::     1 - PortXmitDataSL8-15 2 - PortRcvDataSL0-7 8 - PortRcvDataSL8-15
       -R, --Read <addr,mask>
              Read configuration space record at addr
       -W, --Write <addr,val,mask>
              Write configuration space record at addr
   Addressing Flags
       -G, --Guid     The address specified is a Port GUID
       -L, --Lid   The address specified is a LID
       -s, --sm_port <smlid>     use 'smlid' as the target lid for SA queries.
   Port Selection flags
       -C, --Ca <ca_name>    use the specified ca_name.
       -P, --Port <ca_port>    use the specified ca_port.
   Local port Selection
       Multiple port/Multiple CA support: when  no  IB  device  or  port  is  specified  (see  the  "local  umad
       parameters" below), the libibumad library selects the port to use by the following criteria:
          1. the first port that is ACTIVE.
          2. if not found, the first port that is UP (physical link up).
          If a port and/or CA name is specified, the libibumad library attempts to fulfill the user request, and
          will fail if it is not possible.
          For example:
              ibaddr                 # use the first port (criteria #1 above)
              ibaddr -C mthca1       # pick the best port from "mthca1" only.
              ibaddr -P 2            # use the second (active/up) port from the first available IB device.
              ibaddr -C mthca0 -P 2  # use the specified port only.
   Debugging flags
       -d     raise the IB debugging level.  May be used several times (-ddd or -d -d -d).
       -e     show send and receive errors (timeouts and others)
       -h, --help      show the usage message
       -v, --verbose
              increase the application verbosity level.  May be used several times (-vv or -v -v -v)
       -V, --version     show the version info.
   Configuration flags
       -t, --timeout <timeout_ms> override the default timeout for the solicited mads.
       --config, -z  <config_file> Specify alternate config file.
          Default: /etc/infiniband-diags/ibdiag.conf
FILES
   CONFIG FILE
       /etc/infiniband-diags/ibdiag.conf
       A  global  config  file is provided to set some of the common options for all tools.  See supplied config
       file for details.
EXAMPLES
       ::     vendstat -N 6           # read IS3 or IS4 general information vendstat -w 6           #  read  IS3
              port  xmit wait counters vendstat -i 6 12        # read IS4 port 12 counter group info vendstat -c
              0,1 6 12    # configure IS4 port 12 counter groups for PortXmitDataSL vendstat -c 2,8  6  12     #
              configure IS4 port 12 counter groups for PortRcvDataSL
AUTHOR
       Hal Rosenstock
              <  <hal.rosenstock@gmail.com>  >
                                                   2017-08-21                                        VENDSTAT(8)