Provided by: argyll_2.2.0+repack-1build1_amd64 

NAME
Check - Check accuracy of ICC profile.
DESCRIPTION
Check accuracy of ICC profile, Version 1.6.3
SYNOPSIS
profcheck [-options] data.ti3 iccprofile.icm
-v [level]
Verbosity level (default 1), 2 to print each DE
-c Show CIE94 delta E values
-k Show CIEDE2000 delta E values
-w create VRML visualisation (iccprofile.wrl)
-x Use VRML axes
-m Make VRML lines a minimum of 0.5
-e Color vectors according to delta E
-d devval1,deval2,devvalN
Specify a device value to sort against
-p Sort device value by PCS (Lab) target
-f [illum]
Use Fluorescent Whitening Agent compensation [opt. simulated inst. illum.:
M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp]
-i illum
Choose illuminant for computation of CIE XYZ from spectral data & FWA:
A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp
-o observ
Choose CIE Observer for spectral data:
1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
-I intent
r = relative colorimetric, a = absolute (default)
data.ti3
Test data file
iccprofile.icm
Profile to check against
profcheck September 2014 CHECK(1)